Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 108.126
Filtrar
1.
Trop Anim Health Prod ; 56(4): 139, 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38656618

RESUMEN

We aimed to evaluate the effects of different drying methods for banana residues on the energy metabolism and respirometry of growing lambs. Twenty Santa Inês x Dorper lambs were fed five experimental diets: Tifton 85 grass hay (Control), shade-dried banana leaf hay (LH Shade), shade-dried pseudostem banana hay (PH Shade), sun-dried banana leaf hay (LH Sun), and sun-dried banana pseudostem hay (PH Sun). Nutrient intake and digestibility were assessed in metabolic cages, whereas O2 consumption and CO2, methane, and heat production were measured in a respirometry chamber with animals fed at maintenance and ad libitum levels. Nutrient and energy intake was not influenced by diet. Pseudostem hay had higher apparent digestibility of dry matter (71.5%), organic matter (72.4%), and neutral detergent fiber (58.0%). However, this led to greater energy loss in the form of methane (12.1%). The banana residue hays and drying methods did not alter oxygen consumption, CO2 production, or heat production of animals fed ad libitum or during maintenance. On the other hand, the use of leaf hay resulted in a reduction of 24.7% in enteric methane production of animals fed ad libitum. The inclusion of pseudostem hay is recommended in sheep feedlot diet. This residue provided greater use of DM, however promoted a greater loss of energy in the form of methane, resulting in similar energy consumption. The drying methods did not reduce the availability of nutrients and the sun drying method is recommended, since it is a faster drying method.


Asunto(s)
Alimentación Animal , Dieta , Digestión , Metabolismo Energético , Musa , Animales , Musa/química , Alimentación Animal/análisis , Dieta/veterinaria , Masculino , Oveja Doméstica/fisiología , Fenómenos Fisiológicos Nutricionales de los Animales , Consumo de Oxígeno , Desecación
2.
PLoS One ; 19(4): e0297007, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38635743

RESUMEN

This study aimed to separately compare and rank the effect of various living-low and training-high (LLTH) modes on aerobic and anaerobic performances in athletes, focusing on training intensity, modality, and volume, through network meta-analysis. We systematically searched PubMed, Web of Science, Embase, EBSCO, and Cochrane from their inception date to June 30, 2023. Based on the hypoxic training modality and the intensity and duration of work intervals, LLTH was divided into intermittent hypoxic exposure, continuous hypoxic training, repeated sprint training in hypoxia (RSH; work interval: 5-10 s and rest interval: approximately 30 s), interval sprint training in hypoxia (ISH; work interval: 15-30 s), short-duration high-intensity interval training (s-IHT; short work interval: 1-2 min), long-duration high-intensity interval training (l-IHT; long work interval: > 5 min), and continuous and interval training under hypoxia. A meta-analysis was conducted to determine the standardized mean differences (SMDs) among the effects of various hypoxic interventions on aerobic and anaerobic performances. From 2,072 originally identified titles, 56 studies were included in the analysis. The pooled data from 53 studies showed that only l-IHT (SMDs: 0.78 [95% credible interval; CrI, 0.52-1.05]) and RSH (SMDs: 0.30 [95% CrI, 0.10-0.50]) compared with normoxic training effectively improved athletes' aerobic performance. Furthermore, the pooled data from 29 studies revealed that active intermittent hypoxic training compared with normoxic training can effectively improve anaerobic performance, with SMDs ranging from 0.97 (95% CrI, 0.12-1.81) for l-IHT to 0.32 (95% CrI, 0.05-0.59) for RSH. When adopting a program for LLTH, sufficient duration and work intensity intervals are key to achieving optimal improvements in athletes' overall performance, regardless of the potential improvement in aerobic or anaerobic performance. Nevertheless, it is essential to acknowledge that this study incorporated merely one study on the improvement of anaerobic performance by l-IHT, undermining the credibility of the results. Accordingly, more related studies are needed in the future to provide evidence-based support. It seems difficult to achieve beneficial adaptive changes in performance with intermittent passive hypoxic exposure and continuous low-intensity hypoxic training.


Asunto(s)
Altitud , Rendimiento Atlético , Acondicionamiento Físico Humano , Carrera , Humanos , Hipoxia , Metaanálisis en Red , Consumo de Oxígeno
3.
Physiol Meas ; 45(4)2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38569522

RESUMEN

Objective. The continuous delivery of oxygen is critical to sustain brain function, and therefore, measuring brain oxygen consumption can provide vital physiological insight. In this work, we examine the impact of calibration and cerebral blood flow (CBF) measurements on the computation of the relative changes in the cerebral metabolic rate of oxygen consumption (rCMRO2) from hemoglobin-sensitive intrinsic optical imaging data. Using these data, we calculate rCMRO2, and calibrate the model using an isometabolic stimulus.Approach. We used awake head-fixed rodents to obtain hemoglobin-sensitive optical imaging data to test different calibrated and uncalibrated rCMRO2models. Hypercapnia was used for calibration and whisker stimulation was used to test the impact of calibration.Main results. We found that typical uncalibrated models can provide reasonable estimates of rCMRO2with differences as small as 7%-9% compared to their calibrated models. However, calibrated models showed lower variability and less dependence on baseline hemoglobin concentrations. Lastly, we found that supplying the model with measurements of CBF significantly reduced error and variability in rCMRO2change calculations.Significance. The effect of calibration on rCMRO2calculations remains understudied, and we systematically evaluated different rCMRO2calculation scenarios that consider including different measurement combinations. This study provides a quantitative comparison of these scenarios to evaluate trade-offs that can be vital to the design of blood oxygenation sensitive imaging experiments for rCMRO2calculation.


Asunto(s)
Encéfalo , Imagen Óptica , Consumo de Oxígeno , Oxígeno , Vigilia , Animales , Calibración , Ratones , Encéfalo/metabolismo , Encéfalo/diagnóstico por imagen , Encéfalo/irrigación sanguínea , Oxígeno/metabolismo , Vigilia/fisiología , Consumo de Oxígeno/fisiología , Circulación Cerebrovascular/fisiología , Hemoglobinas/metabolismo , Hemoglobinas/análisis , Masculino , Ratones Endogámicos C57BL , Hipercapnia/metabolismo , Hipercapnia/diagnóstico por imagen
5.
J Sport Exerc Psychol ; 46(2): 66-72, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38580300

RESUMEN

In articles on the methodology of studies investigating affective and enjoyment responses to high-intensity interval training, we noted that, occasionally, exercise conditions described as involving "high" intensity exhibited heart rates that were only as high as, or even lower than, heart rates recorded during comparator conditions described as being of "moderate" intensity. Drs. Vollaard, Metcalfe, Kinghorn, Jung, and Little suggest instead that exercise intensity in high-intensity interval-training studies can be defined in terms of percentages of peak workload. Although we maintain that defining exercise intensity in terms of percentages of maximal heart rate is a suboptimal way to quantify the degree of homeostatic perturbations in response to exercise, we are unconvinced that definitions of intensity relying solely on workload are appropriate for studies investigating affective and enjoyment responses to exercise. The reason is that affect is theorized to have evolved to relay information about homeostatic perturbations to consciousness.


Asunto(s)
Ejercicio Físico , Entrenamiento de Intervalos de Alta Intensidad , Humanos , Ejercicio Físico/psicología , Placer/fisiología , Felicidad , Entrenamiento de Intervalos de Alta Intensidad/métodos , Entrenamiento de Intervalos de Alta Intensidad/psicología , Frecuencia Cardíaca/fisiología , Consumo de Oxígeno/fisiología
6.
Anal Chim Acta ; 1304: 342539, 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38637037

RESUMEN

Three-dimensional (3D)-cultured cells have attracted the attention of researchers in tissue engineering- and drug screening-related fields. Among them, 3D cellular fibers have attracted significant attention because they can be stacked to prepare more complex tissues and organs. Cellular fibers are widely fabricated using extrusion 3D bioprinters. For these applications, it is necessary to evaluate cellular activities, such as the oxygen consumption rate (OCR), which is one of the major metabolic activities. We previously reported the use of scanning electrochemical microscopy (SECM) to evaluate the OCRs of cell spheroids. However, the SECM approach has not yet been applied to hydrogel fibers prepared using the bioprinters. To the best of our knowledge, this is the first study to evaluate the OCR of cellular fibers printed by extrusion 3D bioprinters. First, the diffusion theory was discussed to address this issue. Next, diffusion models were simulated to compare realistic models with this theory. Finally, the OCRs of MCF-7 cells in the printed hydrogel fibers were evaluated as a proof of concept. Our proposed approach could potentially be used to evaluate the OCRs of tissue-engineered fibers for organ transplantation and drug screening using in-vitro models.


Asunto(s)
Hidrogeles , Esferoides Celulares , Humanos , Microscopía Electroquímica de Rastreo , Células Cultivadas , Ingeniería de Tejidos/métodos , Consumo de Oxígeno , Impresión Tridimensional
7.
PeerJ ; 12: e17166, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38563004

RESUMEN

Objectives: To test the hypothesis that 'live high-base train high-interval train low' (HiHiLo) altitude training, compared to 'live low-train high' (LoHi), yields greater benefits on performance and physiological adaptations. Methods: Sixteen young male middle-distance runners (age, 17.0 ± 1.5 y; body mass, 58.8 ± 4.9 kg; body height, 176.3 ± 4.3 cm; training years, 3-5 y; training distance per week, 30-60 km.wk-1) with a peak oxygen uptake averaging ~65 ml.min-1.kg-1 trained in a normobaric hypoxia chamber (simulated altitude of ~2,500 m, monitored by heart rate ~170 bpm; thrice weekly) for 3 weeks. During this period, the HiHiLo group (n = 8) stayed in normobaric hypoxia (at ~2,800 m; 10 h.day-1), while the LoHi group (n = 8) resided near sea level. Before and immediately after the intervention, peak oxygen uptake and exercise-induced arterial hypoxemia responses (incremental cycle test) as well as running performance and time-domain heart rate variability (5-km time trial) were assessed. Hematological variables were monitored at baseline and on days 1, 7, 14 and 21 during the intervention. Results: Peak oxygen uptake and running performance did not differ before and after the intervention in either group (all P > 0.05). Exercise-induced arterial hypoxemia responses, measured both at submaximal (240 W) and maximal loads during the incremental test, and log-transformed root mean square of successive R-R intervals during the 4-min post-run recovery period, did not change (all P > 0.05). Hematocrit, mean reticulocyte absolute count and reticulocyte percentage increased above baseline levels on day 21 of the intervention (all P < 0.001), irrespective of group. Conclusions: Well-trained runners undertaking base training at moderate simulated altitude for 3 weeks, with or without hypoxic residence, showed no performance improvement, also with unchanged time-domain heart rate variability and exercise-induced arterial hypoxemia responses.


Asunto(s)
Altitud , Tolerancia al Ejercicio , Masculino , Humanos , Adolescente , Consumo de Oxígeno/fisiología , Hipoxia , Adaptación Fisiológica , Oxígeno
8.
Scand J Med Sci Sports ; 34(4): e14629, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38646853

RESUMEN

BACKGROUND: Athletes commonly use creatine, caffeine, and sodium bicarbonate for performance enhancement. While their isolated effects are well-described, less is known about their potential additive effects. METHODS: Following a baseline trial, we randomized 12 endurance-trained males (age: 25 ± 5 years, VO2max: 56.7 ± 4.6 mL kg-1 min-1; mean ± SD) and 11 females (age: 25 ± 3 years, VO2max: 50.2 ± 3.4 mL kg-1 min-1) to 5 days of creatine monohydrate (0.3 g kg-1 per day) or placebo loading, followed by a daily maintenance dose (0.04 g kg-1) throughout the study. After the loading period, subjects completed four trials in randomized order where they ingested caffeine (3 mg kg-1), sodium bicarbonate (0.3 g kg-1), placebo, or both caffeine and sodium bicarbonate before a maximal voluntary contraction (MVC), 15-s sprint, and 6-min time trial. RESULTS: Compared to placebo, mean power output during 15-s sprint was higher following loading with creatine than placebo (+34 W, 95% CI: 10 to 58, p = 0.008), but with no additional effect of caffeine (+10 W, 95% CI: -7 to 24, p = 0.156) or sodium bicarbonate (+5 W, 95% CI: -4 to 13, p = 0.397). Mean power output during 6-min time trial was higher with caffeine (+12 W, 95% CI: 5 to 18, p = 0.001) and caffeine + sodium bicarbonate (+8 W, 95% CI: 0 to 15, p = 0.038), whereas sodium bicarbonate (-1 W, 95% CI: -7 to 6, p = 0.851) and creatine (-6 W, 95% CI: -15 to 4, p = 0.250) had no effects. CONCLUSION: While creatine and caffeine can enhance sprint- and time trial performance, respectively, these effects do not seem additive. Therefore, supplementing with either creatine or caffeine appears sufficient to enhance sprint or short intense exercise performance.


Asunto(s)
Rendimiento Atlético , Cafeína , Creatina , Sustancias para Mejorar el Rendimiento , Bicarbonato de Sodio , Humanos , Cafeína/farmacología , Cafeína/administración & dosificación , Bicarbonato de Sodio/administración & dosificación , Bicarbonato de Sodio/farmacología , Masculino , Creatina/administración & dosificación , Creatina/farmacología , Adulto , Femenino , Adulto Joven , Sustancias para Mejorar el Rendimiento/administración & dosificación , Sustancias para Mejorar el Rendimiento/farmacología , Rendimiento Atlético/fisiología , Resistencia Física/efectos de los fármacos , Entrenamiento Aeróbico , Método Doble Ciego , Consumo de Oxígeno/efectos de los fármacos
9.
J Int Soc Sports Nutr ; 21(1): 2340574, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38606895

RESUMEN

BACKGROUND: Growing evidence supports the ergogenic effects of creatine supplementation on muscle power/strength, but its effects on endurance performance remain unclear. We assessed the effects of high-dose short-term creatine supplementation in professional cyclists during a training camp. METHODS: The study followed a double-blind, randomized parallel design. Twenty-three professional U23 cyclists (19 ± 1 years, maximum oxygen uptake: 73.0 ± 4.6 mL/kg/min) participated in a 6-day training camp. Participants were randomized to consume daily either a recovery drink (containing carbohydrates and protein) with a 20-g creatine supplement (creatine group, n = 11) or just the recovery drink (placebo group, n = 12). Training loads and dietary intake were monitored, and indicators of fatigue/recovery (Hooper index, countermovement jump height), body composition, and performance (10-second sprint, 3-, 6-, and 12-minute time trials, respectively, as well as critical power and W') were assessed as study outcomes. RESULTS: The training camp resulted in a significant (p < 0.001) increase of training loads (+50% for total training time and + 61% for training stress score, compared with the preceding month) that in turn induced an increase in fatigue indicators (significant time effect [p < 0.001] for delayed-onset muscle soreness, fatigue, and total Hooper index) and a decrease in performance (significant time effect [p = 0.020] for critical power, which decreased by -3.8%). However, no significant group-by-time interaction effect was found for any of the study outcomes (all p > 0.05). CONCLUSIONS: High-dose short-term creatine supplementation seems to exert no consistent beneficial effects on recovery, body composition or performance indicators during a strenuous training period in professional cyclists.


Asunto(s)
Rendimiento Atlético , Humanos , Rendimiento Atlético/fisiología , Creatina , Consumo de Oxígeno , Oxígeno/metabolismo , Fatiga , Método Doble Ciego , Suplementos Dietéticos , Músculo Esquelético
10.
Sensors (Basel) ; 24(7)2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38610469

RESUMEN

Aerobic capacity plays a crucial role in football performance, making it a focal point in training processes. Small-sided games (SSGs) are widely used in football training, but the relationship between aerobic capacity and running performance during SSGs remains unclear. The aim of this study was to investigate possible correlations between maximum oxygen uptake (VO2max) and running performance in youth football players in SSGs (4:4, 3:3, 2:2, 1:1) with three different pitch sizes per player (150, 100, 75 m2/player). Sixteen male U15 football players participated in the study. Players underwent the Yo-Yo intermittent recovery test level 1, and their VO2max was estimated based on their performance. Subsequently, players participated in SSGs wearing GPS devices to measure internal and external load. Pearson or Spearman correlation was applied for statistical analysis depending on the normal distribution of the data. The results reveal that, for 4:4 and 3:3 relationships, larger pitches led to a greater impact of aerobic capacity (total distance (TD): 4:4, 150 m2/pl, r = 0.715, p = 0.002; 100 m2/pl, r = 0.656, p = 0.006; 75 m2/pl, r = 0.586, p = 0.017). In the 2:2 relationship, the opposite was observed, with more correlations appearing on smaller pitches (TD: 2:2, 100 m2/pl, r = 0.581, p = 0.018; 75 m2/pl, r = 0.747, p < 0.001). In the 1:1 relationship, correlations with VO2max, total distance, and speed were observed only on the larger pitch. In conclusion, the aerobic capacity of young football players can influence running performance indicators in SSGs. Therefore, aerobic capacity could serve as a criterion for team composition, making SSGs more competitive. Additionally, the variation in correlations in the 2:2 relationship and their limited presence in the 1:1 relationship may be attributed to technical-tactical factors, such as increased ball contacts and one-on-one situations typically occurring in smaller setups.


Asunto(s)
Fútbol , Adolescente , Humanos , Masculino , Gluconato de Sodio Antimonio , Oxígeno , Consumo de Oxígeno
12.
Scand J Med Sci Sports ; 34(4): e14625, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38597357

RESUMEN

Heightened sensation of leg effort contributes importantly to poor exercise tolerance in patient populations. We aim to provide a sex- and age-adjusted frame of reference to judge symptom's normalcy across progressively higher exercise intensities during incremental exercise. Two-hundred and seventy-five non-trained subjects (130 men) aged 19-85 prospectively underwent incremental cycle ergometry. After establishing centiles-based norms for Borg leg effort scores (0-10 category-ratio scale) versus work rate, exponential loss function identified the centile that best quantified the symptom's severity individually. Peak O2 uptake and work rate (% predicted) were used to threshold gradually higher symptom intensity categories. Leg effort-work rate increased as a function of age; women typically reported higher scores at a given age, particularly in the younger groups (p < 0.05). For instance, "heavy" (5) scores at the 95th centile were reported at ~200 W (<40 years) and ~90 W (≥70 years) in men versus ~130 W and ~70 W in women, respectively. The following categories of leg effort severity were associated with progressively lower exercise capacity: ≤50th ("mild"), >50th to <75th ("moderate"), ≥75th to <95th ("severe"), and ≥ 95th ("very severe") (p < 0.05). Although most subjects reporting peak scores <5 were in "mild" range, higher scores were not predictive of the other categories (p > 0.05). This novel frame of reference for 0-10 Borg leg effort, which considers its cumulative burden across increasingly higher exercise intensities, might prove valuable to judging symptom's normalcy, quantifying its severity, and assessing the effects of interventions in clinical populations.


Asunto(s)
Prueba de Esfuerzo , Pierna , Masculino , Humanos , Femenino , Valores de Referencia , Ergometría , Ejercicio Físico , Consumo de Oxígeno
14.
Kardiologiia ; 64(2): 34-42, 2024 Feb 29.
Artículo en Ruso | MEDLINE | ID: mdl-38462802

RESUMEN

AIM: To determine the correlation between the results of the 6-minute walk test (6MWT) and peak oxygen consumption (VO2peak) for populations of patients with chronic heart failure with pronounced clinical and demographic differences; to study a possibility of indirect measurement of VO2peak based on the results of 6MWT using the formulas available from the literature. MATERIAL AND METHODS: Two databases were analyzed: 50 patients included in the AEROFIT study (group A), and 31 patients from the Almazov National Medical Research Center (group B). The inclusion criteria were the availability of data from the cardiopulmonary stress test and the 6MWT. The possibility of predicting VO2peak was calculated based on the results of 6MWT using the formulas reported in the literature (L. P. Cahalin et al., 1996; R. M. Ross et al., 2010; R. A. Adedoyin et al., 2010). The predictive accuracy of the models was assessed using the coefficient of determination (R2). The relationship between functional and clinical-demographic indicators was assessed using the Pearson or Spearman correlation analysis. RESULTS: The study groups differed significantly in all parameters, except for the proportion of men and the mean VO2peak. Group B patients were 20 years younger than group A patients, had a lower left ventricular ejection fraction (24.06±7.75 and 41.52±10.48 %, respectively; p<0.001), and covered a 130 m shorter distance in the 6MWT. Despite the absence of a significant difference in VO2peak between groups A and B (13.6 and 13.1 ml / kg / min, respectively; p=0.6581), 61 % of group B patients and 20% of group A belonged to Weber functional class IV. In group A, the 6MWT distance correlated closely with VO2peak (R=0.78; p<0.01) and weakly with age (R=0.4) and body mass index (R=0.3). In group B, the 6MWT distance correlated only with VO2peak (R=0.77; p<0.01). For group A, the R.M. Ross et al. model demonstrated high accuracy in determining the mean VO2peak value with a 0.06% prediction error normalized to measured VO2peak. For group B, none of the models showed satisfactory predictive accuracy. The Ross and Cahalin models showed the best coefficients of determination for groups A and B: Group A, Ross et al. (R2=0.58) and Cahalin et al. (R2=0.59); Group B, Ross et al. (R2=0.59) and Cahalin et al. (R2=0.6). CONCLUSION: In two groups of patients with a statistically insignificant difference in the mean values of VO2peak, the mean values of 6MWT distance were significantly different, although these indicators correlated closely. The VO2peak prediction models showed satisfactory accuracy for estimation of mean VO2, but poor accuracy for estimation of individual values. A better predictive accuracy is determined by similar clinical and demographic characteristics between the training and testing populations, and likely also by models based on larger, more diversified populations.


Asunto(s)
Insuficiencia Cardíaca , Función Ventricular Izquierda , Masculino , Humanos , Prueba de Paso , Volumen Sistólico , Consumo de Oxígeno , Prueba de Esfuerzo/métodos , Enfermedad Crónica , Insuficiencia Cardíaca/diagnóstico
15.
Methods Mol Biol ; 2761: 49-55, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38427228

RESUMEN

High-resolution mitochondrial respirometry is a modern technique that enables to measure mitochondrial respiration in various cell types. It contains chambers with oxygen sensors that measure oxygen concentration via polarography and calculate its consumption. The chamber contains plastic stoppers with injection ports that allow the injection of samples and different substrates, inhibitors, and uncoupler substances to measure mitochondrial respiration with high efficiency. These substances act on the mitochondrial electron transport chain (ETC) and help to assess the mitochondrial ATP production capacity and oxidative phosphorylation. The respirograph obtained with the help of software represents the oxygen consumption in each stage after adding different reagents.


Asunto(s)
Respiración de la Célula , Roedores , Animales , Mitocondrias/metabolismo , Fosforilación Oxidativa , Consumo de Oxígeno , Encéfalo/metabolismo , Oxígeno/metabolismo
16.
Skin Res Technol ; 30(3): e13638, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38454567

RESUMEN

BACKGROUND: Skin wound healing is a complex mechanism which requires a lot of energy, mainly provided by mitochondrial respiration. However, little is known about the mitochondrial bioenergetics of mice skin. We sought to develop a microplate-based assay to directly measure oxygen consumption in whole mice skin with the goal of identifying mitochondrial dysfunction in diabetic skin using an extracellular flux. MATERIALS AND METHODS: Different parameters were optimized to efficiently measure the oxygen consumption rate (OCR). First, the most pertinent skin side of wild-type mice was first determined. Then, concentrations of mitochondrial inhibitors were then optimized to get the best efficacy. Finally, punch sizes were modulated to get the best OCR profile. RESULTS: Dermis had the best metabolic activity side of the skin. Unlike the increased concentrations of carbonyl cyanide-p-trifluoromethoxyphenylhydrazone (FCCP) and rotenone/antimycin A, which showed no improvement of these drugs' effects, varying the skin punch size was successful. Finally, type II diabetic (T2D) skin produced less ATP through mitochondrial metabolism and had a greater non-mitochondrial oxygen consumption than wild-type or type I diabetic (T1D) skin. CONCLUSION: Here we designed, for the first time, a reliable protocol to measure mitochondria function in whole mouse skin. Our optimized protocol was valuable in assessing alterations associated with diabetes and could be applied to future studies of pathological human skin metabolism.


Asunto(s)
Diabetes Mellitus Experimental , Ratones , Humanos , Animales , Diabetes Mellitus Experimental/inducido químicamente , Diabetes Mellitus Experimental/metabolismo , Mitocondrias/metabolismo , Metabolismo Energético , Consumo de Oxígeno , Carbonil Cianuro p-Trifluorometoxifenil Hidrazona/metabolismo , Carbonil Cianuro p-Trifluorometoxifenil Hidrazona/farmacología
17.
PeerJ ; 12: e16940, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38426136

RESUMEN

Background: The maximal running speed (VMAX) determined on a graded treadmill test is well-recognized as a running performance predictor. However, few studies have assessed the variables that predict VMAX in recreationally active runners. Methods: We used a mathematical procedure combining Fick's law and metabolic cost analysis to verify the relation between (1) VMAX versus anthropometric and physiological determinants of running performance and, (2) theoretical metabolic cost versus running biomechanical parameters. Linear multiple regression and bivariate correlation were applied. We aimed to verify the biomechanical, physiological, and anthropometrical determinants of VMAX in recreationally active runners. Fifteen recreationally active runners participated in this observational study. A Conconi and a stead-steady running test were applied using a heart rate monitor and a simple video camera to register the physiological and mechanical variables, respectively. Results: Statistical analysis revealed that the speed at the second ventilatory threshold, theoretical metabolic cost, and fat-mass percentage confidently estimated the individual running performance as follows: VMAX = 58.632 + (-0.183 * fat percentage) + (-0.507 * heart rate percentage at second ventilatory threshold) + (7.959 * theoretical metabolic cost) (R2 = 0.62, p = 0.011, RMSE = 1.50 km.h-1). Likewise, the theoretical metabolic cost was significantly explained (R2 = 0.91, p = 0.004, RMSE = 0.013 a.u.) by the running spatiotemporal and elastic-related parameters (contact and aerial times, stride length and frequency, and vertical oscillation) as follows: theoretical metabolic cost = 10.421 + (4.282 * contact time) + (-3.795 * aerial time) + (-2.422 * stride length) + (-1.711 * stride frequency) + (0.107 * vertical oscillation). Conclusion: Critical determinants of elastic mechanism, such as maximal vertical force and vertical and leg stiffness were unrelated to the metabolic economy. VMAX, a valuable marker of running performance, and its physiological and biomechanical determinants can be effectively evaluated using a heart rate monitor, treadmill, and a digital camera, which can be used in the design of training programs to recreationally active runners.


Asunto(s)
Prueba de Esfuerzo , Consumo de Oxígeno , Antropometría , Fenómenos Biomecánicos , Consumo de Oxígeno/fisiología , Proyectos de Investigación , Humanos
18.
Respir Res ; 25(1): 121, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38468264

RESUMEN

BACKGROUND: Cardiac dysfunction from pulmonary vascular disease causes characteristic findings on cardiopulmonary exercise testing (CPET). We tested the accuracy of CPET for detecting inadequate stroke volume (SV) augmentation during exercise, a pivotal manifestation of cardiac limitation in patients with pulmonary vascular disease. METHODS: We reviewed patients with suspected pulmonary vascular disease in whom CPET and right heart catheterization (RHC) measurements were taken at rest and at anaerobic threshold (AT). We correlated CPET-determined O2·pulseAT/O2·pulserest with RHC-determined SVAT/SVrest. We evaluated the sensitivity and specificity of O2·pulseAT/O2·pulserest to detect SVAT/SVrest below the lower limit of normal (LLN). For comparison, we performed similar analyses comparing echocardiographically-measured peak tricuspid regurgitant velocity (TRVpeak) with SVAT/SVrest. RESULTS: From July 2018 through February 2023, 83 simultaneous RHC and CPET were performed. Thirty-six studies measured O2·pulse and SV at rest and at AT. O2·pulseAT/O2·pulserest correlated highly with SVAT/SVrest (r = 0.72, 95% CI 0.52, 0.85; p < 0.0001), whereas TRVpeak did not (r = -0.09, 95% CI -0.47, 0.33; p = 0.69). The AUROC to detect SVAT/SVrest below the LLN was significantly higher for O2·pulseAT/O2·pulserest (0.92, SE 0.04; p = 0.0002) than for TRVpeak (0.69, SE 0.10; p = 0.12). O2·pulseAT/O2·pulserest of less than 2.6 was 92.6% sensitive (95% CI 76.6%, 98.7%) and 66.7% specific (95% CI 35.2%, 87.9%) for deficient SVAT/SVrest. CONCLUSIONS: CPET detected deficient SV augmentation more accurately than echocardiography. CPET-determined O2·pulseAT/O2·pulserest may have a prominent role for noninvasive screening of patients at risk for pulmonary vascular disease, such as patients with persistent dyspnea after pulmonary embolism.


Asunto(s)
Cardiopatías , Hipertensión Pulmonar , Humanos , Prueba de Esfuerzo , Pulmón , Circulación Pulmonar , Tolerancia al Ejercicio , Consumo de Oxígeno
19.
Nutrients ; 16(5)2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38474825

RESUMEN

Chlorella supplementation is reported to improve V˙O2max following extended supplementation periods (~3 weeks). However, there is little research on its impact over submaximal exercise intensities and following shorter supplementation regimens. This study aimed to investigate the efficacy of 6 g/day 2-day chlorella supplementation on exercise performance in healthy young adults. Twenty young healthy adults (Males = 16, Females = 4) (Age 22 ± 6 years, V˙O2max 42.7 ± 9.6 mL/(kg·min)) were recruited for this double-blinded, randomised cross-over study. Participants ingested 6 g/day of chlorella or a placebo for 2 days, with a one-week washout period between trials. Exercise testing consisted of a 20 min submaximal cycle at 40% of their work rate max (WRmax) (watts), followed by an incremental V˙O2max test. Lactate (mmol/L), heart rate (b/min), oxygen consumption (mL/(kg·min)), O2 pulse (mL/beat), respiratory exchange ratio (RER), and WRmax were compared across conditions. Following chlorella supplementation, blood lactate levels were significantly lower (p < 0.05) during submaximal exercise (3.05 ± 0.92 mmol/L vs. 2.67 ± 0.79 mmol/L) and following V˙O2max tests (12.79 ± 2.61 mmol/L vs. 11.56 ± 3.43 mmol/L). The O2 pulse was significantly higher (p < 0.05) following chlorella supplementation during submaximal (12.6 ± 3.5 mL/beat vs. 13.1 ± 3.5 mL/beat) and maximal exercise intensity (16.7 ± 4.6 mL/beat vs. 17.2 ± 4.5 mL/beat). No differences existed between conditions for oxygen consumption, RER, V˙O2max, or WRmax. A total of 2 days of 6 g/day chlorella supplementation appears to lower the blood lactate response and increase O2 pulse during both submaximal and maximal intensity exercise but did not lead to any improvements in V˙O2max.


Asunto(s)
Chlorella , Ácido Láctico , Masculino , Adulto Joven , Femenino , Humanos , Adolescente , Adulto , Frecuencia Cardíaca , Estudios Cruzados , Consumo de Oxígeno/fisiología , Prueba de Esfuerzo , Suplementos Dietéticos
20.
Sensors (Basel) ; 24(5)2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-38474946

RESUMEN

Roller skiing is one primary form of training method as it is an off-snow equivalent to cross-country (XC) skiing during the dry land preseason training, but the results could only be applied to on-snow skiing with appropriate caution. The aim of this present study was to investigate the similarities and differences in roller skiing and on-snow skiing with the diagonal stride (DS) technique. Six youth (age: 14.3 ± 2.9 years) skiers participated in this study. Two high-definition video camcorders and FastMove 3D Motion 2.23.3.3101 were used to obtain the three-dimensional kinematic data. The cycle characteristics and joint angle ROM of the DS technique while skiing on different surfaces were similar. Almost all joint angle-time curves that were obtained from roller skiing showed a moderate-to-high degree of similarity to the angle-time curves obtained from on-snow skiing, except the hip adduction-abduction angle. The differences between roller skiing and on-snow skiing were mainly found in the body and calf anteversion angles, and the joint angles at critical instants. DS roller skiing can simulate DS on-snow skiing to a large extent in youth athletes. The hip movement, knee flexion, and calf anteversion at ski/roller ski touchdown and take-off, pole inclination at pole touchdown, body anteversion angle, and trunk anteversion angle at pole touchdown were the points that required caution when transferring preseason practice roller skiing to on-snow skiing.


Asunto(s)
Esquí , Humanos , Adolescente , Niño , Consumo de Oxígeno , Pierna , Fenómenos Biomecánicos , Movimiento (Física)
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...